It is connected via a heavy metal cable to a ground rod which is driven into the ground nearby. If installed correctly this arrester offers an added level of protection against lightning damage. Difference between surge arrester, lightning arrester and. A surge arrester may be compared to a relief valve on a boiler or hot water heater. Installation instructions for lightning arrester kit kit. The basis of conventional lightning protection technology. Production of high voltage surge arresters type pexlim english wmv movie seismic test high voltage surge arresters type pexlim english wmv movie excountii animation english exe movie data sheet abb ability wireless monitor for surge arrester english pdf data sheet. When a powerful electric surge travels from the power system to the surge arrester, the high voltage current is sent directly to the insulation or to the ground to. Application of the external lightning, surge arrester, grounding, equipotential systems is installed by expert enginner staff. The surge arresters are produced in three main titles, high voltage surge arresters.
So it will break down the insulation of the lightning arrestor for a moment, so voltage surge can be discharged toward the ground. A lightning arrester, surge arrester or line arrester is a device used on electrical power systems and telecommunications systems to protect the insulation and conductors of the system from the damaging effects of lightning. These materials have a unique property of becoming conductive when a very high electric pote. Metaloxide surge arresters in highvoltage power systems. Apr 11, 2016 a lightning arrester is a device, used on power systems, that contains billions of electronic switches that divert lightning around sensitive equipment and saves 44. The normal operation is defined as condition when no surge is presented and the surge arrester is subjected to normal system voltage only. Types of surge arresters rod gap arrester horn gap arrester multigap arresters expulsion type arrester valve type arresters 46. In an extrahigh voltage ac system the surge diverter is used to protect the generators.
In class b, c class section 16mm2 minimum we have to use a minimum of 6 mm2. Pdf application and analysis for surge arrester on. Report of the federal interagency lightning protection user group june 2001. With the lcm500 surge arrester test set, it takes less than 15 minutes to establish that your surge arresters are healthy and the transformer is still protected. The resistance regulates the level of current allowed into the arrester at once, and the choke coil increases the reactivity of the arrester when transient frequency occurs. In power systems, lightning arrestors are used to provide protection against surges and lightning strikes.
Nov 29, 2016 study of lightning arrester working principal and working of lighning and construction of lightning arrester. Difference between surge arrester, lightning arrester and lightning rod. Surge arresters and lightning current arresters from dehn offer reliable protection against these hazards. Lightning, is a form of visible discharge of electricity between rain clouds or between a rain cloud and the earth. It starts with a specified arrester in a buildings primary supply or subdistribution. The station class arrester has the best protection capability and is the most expensive. Electrical4u is dedicated to the teaching and sharing of all things related to electrical and. Classes of surge arresters station class intermediate class distribution class secondary class 33. The lightning arrester is located close to the equipment that is to be protected. This places tough demands on their ability to fail safe and not risk damage to equipment or injury to personnel in the vicinity. Ieeeiec lightning arrester arresters for ac and dc applications.
In large substations, arrestors should be installed at takeoff points of the lines and of the terminal apparatus. A simple guide to selection of lightning and surge protection please note that this is a very simple summary and must be read in conjunction with the relevant code sans 101421. When a high voltage greater than the normal line voltage. Tasks and operating principles of mo arresters 5 tasks and operating principles of metaloxide arresters surge arresters or short, arresters constitute an indispensable aid to insulation coordination1 in electrical power supply systems. Mar 28, 2008 a lightning rod, sometimes called a lightning arrester is something you mount on top of your house. The lower the arrester voltage rating, the lower the discharge voltage, and the better the protection of the insulation system. A surge arrester may be inexpensive, but it has an important role in protecting your transformers. They are usually connected between phase and ground in an ac system and pole and ground in case of the dc system. To ensure proper protection, you must know which type of lightning arrester to use and what its rating means.
This guide explains the power factor test procedure of these surge arresters. The surge arrester is a product which is insulated up to a predetermined voltage value and which is manufactured to discharge overload to the ground by passing through the determined voltage value. Surge arresters and lightning current arresters from dehn. This article introduces in such aspects as the working principle of line surge arrester and effect of lightning protection, and also explores. Thunderester lightning protection is an electronic based lightning protection system working principle on piezoelectric technology to protect the entire structure of a building in the event of direct lightning strikes, it allows lightning current to follow a low resistance path through the down conductor to ground, thus protect the structure from physical damage. Installation instructions for lightning arrester kit kit number 5300534 this kit is intended for use with the binmaster directional wireless system, wl 19d. How to protect your house from lightning national lightning. Between the two terminals is a gap of either air or a material of high resistance. Lightning arresters are connected between the phase conductors and ground. Contents definition of surge arresters 02 portfolio overview 04 history timeline 06 movs. While lightning current arresters class 1 are used to protect against direct lightning surge currents, surge arresters class 2 protect equipment from induced surges in electrical wiring. The earthing screen and ground wires can well protect the electrical system against direct lightning strokes but they fail to provide protection against traveling waves, which may reach the terminal apparatus.
Compared with a traditional lightning arrester, the active lightning arrester can absorb and save energy with variations of. A surge arrester is a device that protects electrical power systems from damages caused by lightning. When the pressure is returned to normal, the safety valve is ready for the next operation. Lightning arrester normally a spark gap device connected between each leg of a pow. But its construction and working principle is very different from the lightening rod. Ieeeiec lightning arresters ieeeiec lightning arresters. Working 446,000 35,000 168,000 ultimate 637,000 70, 800 240,000 silicone housed surge arresters for high voltage comparison of cantilever strength compared typical porcelain arresters. Working of surge arresters normal operation occurrence of high voltage function as a non linear resistor 34. This report investigates the discharge mechanism and discusses the principles of lightning protection and the way this is applied to the protection of structures.
Mar 30, 2011 lighting and voltage surge lightning can create voltage surges in several of the following ways. When a voltage surge traveling along the conductor reaches the point at which a lightning arrestor is installed it breaks down the insulation of the arrester momentarily, allowing the voltage surge to discharge to ground. A surge arrester is a device to protect electrical equipment from overvoltage transients caused by external lightning or internal switching events. The non linear lightning arrester basically consists of set of spark gaps in series with the silicon carbide non linear resistor elements. The values are also compared with arrester of similar make and type, operating under similar conditions over a period of time. It is generally understood that for mechanical systems, such as the polymer housed arrester, the working strength mdlc static is 40% of the breaking force or ultimate strength. Lightning arresters las are among the most misunderstood and misapplied protective devices in our industry. As soon as the system voltage drops below the predetermined value. Principle and evaluation method of active lightning arrester. Board type b class and c class surge arresters must be connected in parallel to the system. Pdf application and analysis for surge arrester on lightning. We mainly provide best with top quality and competitive val. The working principle of an active lightning arrester is described. It is a pointed long metal rod or several of them that is mounted on the roof so that it is the highest object.
Surge arresters are used to protect transmission lines, transformer or other equipments from transient voltage. The kit employs a polyphaser surge protector rated for the 900mhz frequency band of the. Design of lightning arresters for electrical power systems. E lightning conductor the main function of the lightning protection system installed on the existing building is to capture a lightning stroke and then conduct discharge current safety to the ground. Its working principle depends on piezoelectric technology to protect the entire structure of a building in the event of direct lightning strikes, it allows lightning current to follow a low resistance path through the down conductor to ground, thus protect the structure from physical damage. Check insulator withstand capability of the housing use paragraph 8. Professional surge protection for building installations. This principle forms the basis of the socalled early streamer emission devices which have been developed in recent years. Arresters 101 covers the fundamentals of surge protection on transmission and distribution power systems. Yet, with the increasing use of sensitive electronic equipment, theyre almost a must, because they divert the effects of extremely shortterm overvoltages on an electrical. Adding a lightning arrester to the system redirects the charges in the lightning to the ground. Lightning protection principles knowledge of the mechanism of the lightning discharge enables an understanding of the way in which lightning detection and warning systems operate. Short circuit behaviour surge arresters and counters james taylor, abb power products, ludvika, sweden abstract by nature, a surge arrester may be overloaded at any time as part of its normal duty.
Jul 17, 2017 the horn is connected to two different wires. Thunderester lightning protection is an electronic based lightning protection system. Why do we make the rating of surge arrester kv always less. A lightning arrester alternative spelling lightning arrestor also called lightning diverter is a device used on electric power systems and telecommunication systems to protect the insulation and conductors of the system from the damaging effects of lightning. The lightning discharge the transient discharge of electric current that occurs between a negative charge centre and a positively charged region is a lightning flash. The discharge voltage, v10, for this arrester is 248kv for a 10ka, 8 x 20s current wave shape. Zno gapless lightning arrester or surge arrester electrical4u. This arrester provides protection against all types of ac and dc over voltages. Surge arrester is used to protect the circuit or electrical equipment from high voltage transient or electrical surges.
Sites above marked with the contain pdf copies of this application guide. Lightning protection and surge arrester application on nb. The typical lightning arrester has a highvoltage terminal and a ground terminal. When a powerful electric surge travels from the power system to the surge arrester, the high voltage current is sent directly to the insulation or to the ground to avoid damaging the system. The success of such a device depends on the timing of the corona initiation in relation to the downward leader approach and the rapidity with which the leaders can attach compared with the time that. The purpose of a surge lighting arrester is to limit the over voltages that may occur across transformers and other electrical apparatus due either to lightning or switching surges. Arresterworks, consultants, arrester, arrestor, surge. Both outages resulted from lightning arrester failures which were attributed to a lightning strike which exceeded the arresters energy carrying capability. This article introduces in such aspects as the working principle of line surge arrester and effect of lightning protection, and also explores application for lightning arrester of distribution. From 2000 to 2007, two outages were experienced under lightning conditions. The application and selection of lightning arresters. Determine where the arrester should be physically located. Early streamer emmission lightning protection grounding.
The working of surge arrester is, whenever lightning or power surge hits a particular electrical system, then it will harm the entire system as well as electrical devices that are connected to this system because these devices work at a fixed voltage range if the voltage received by the electrical devices is high than the fixed voltage. Lightning arrester should be located close to the equipment that it is expected to protect. Spd surge protective device this is also a surge diverter, but generally for voltages well below volts. Arrester information required d length of arrester column in meters use overall dimensions from catalog data n number of parallel columns of metaloxide. How to protect your house and its contents from lightning.
Under all conditions lightning protection is necessary to provide protection to personnel working in buildings. Why do we make the rating of surge arrester kv always. If the test voltage is exceeded in operation, the safety effect of the insulation is. How does a lightning arrestor work,lightning arrestor. Lightning arrestor conventional lightning protection. Principle for selecting arresters according to iec 664 din vde 0110 part 1. Between it and the horn is a resistance and a choke coil. Arresterworks is an international consulting firm focused on assisting others in improving power system reliability through design, production and application of arresters to mitigate the effect of lightning and other transients. Understanding the arrester datasheet nema arresters. What is the difference between lightning arrester and. The effects of lightning currents and surge voltages are many and varied.
Also called a surge protection device spd or transient voltage surge suppressor tvss, this class of device is used to protect equipment in power transmission and distribution systems. During normal system operating voltage conditions, the spark gaps are non conducting and isolate. To prevent damage to electrical equipment, surge protection considerations are paramount to a welldesigned electrical. Lightning arrestor working principle is, once the voltage surge travels throughout the conductor then it reaches the location of the arrestor where it is installed. The zinc oxide has highly nonuniform current voltage iv characteristics. For consumer equipment protection, different products.
Usually, the arrester is connected between system and ground in parallel with protected equipment. Ten 10 sets of approved drawings and operation and maintenance manuals shall be submitted to the chief engineer, engg. One terminal of the arrester is connected to the device and the other terminal is connected to a rod or wire of low resistance that is buried in the ground. The electric discharge is seen in the form of a brilliant arc, sometimes several kilometres long, stretching between the discharge points. Short circuit behaviour surge arresters and counters. A lightning arrester is the first component in a three step process designed to eliminate damaging voltage spikes from damaging electrical and electronic devices. The arrester which uses zinc oxide semiconductor as a resistor material, such type of arrester is known as a metal oxide surge arrester or zno diverter. Its easiest to think of an arrestor and this goes for a lightning arrestor as well as a form of protection from external problems, such as those caused by lighting or power grid complications. Nov 19, 2017 for the love of physics walter lewin may 16, 2011 duration.
It can strike the overhead power line which enters your house, or a main power line that is blocks away from your home. A typical surge arrester has both a ground terminal and a highvoltage terminal. Working principle of zinc oxide lightning arrester. Silicon carbide lightning arresters working principle. If the voltage level in the power line exceeds the arrester rated voltage, the electrons behave di erently and create a low resistance path that conducts the injected lightning current to the ground system. In an ac system, separate arrester is provided for each phase. Professional surge protection is provided by specialist electrical companies.
Arresters are typically installed near critical appliances or points of entry, such as an electrical panel or near a generator. This department provides a secondary crossinspection for work in process and finished products, ensuring quality is achieved throughout. Reliable long term operating stability since the zinc oxide surge arresters have no gaps, the zinc oxide resistors are exposed to a long. Each piece of electrical equipment in an electrical system needs to be protected from voltage surges. This is the steadystate working strength of an arrester should it be used to support bus or cable.
It will release high pressure until a normal operating condition is reached. Many factors like system voltages, basic impulse insulation level, arrestor rating, station layout. Because condition assessment is not a low cost endeavor arrester condition monitoring is most often performed only at critical locations where an arrester failure could cause serious ramifications in the form of an outage and loss of revenue. Because the corporation established, we have been committed to buy in lightning arrester pdf sales and service, weve regularly ad. A lightning arrester is essentially a collection of billions of microscopic junctions of metal oxide grains that turn on and off in microseconds to form a current path from the top terminal to the ground terminal of the arrester. A lightning arrester alternative spelling lightning arrestor also called lightning diverter is a. The lightning arresters or surge diverts provide protection against such surges. Clamp the over voltage down below the bil of the equipment 3. Note that all the circuits in figure 6 are simplified to show the principles of. A surge arrestor, on the other hand, works to mitigate specific types of surges.